Edit-OemLine
PackageDeployment Module Help |
Package Deployment Module |
Edit-OemLine Cmdlet |
Version 4.0.0.5 |
Edit-OemLine
Synopsis
Modify OEM File
Syntax
Edit-OemLine [-FileName] <String> [[-Arguments] <String>] [[-OldLine] <String>] [-ConfirmChanges] [-ContinueOnError] [-ReturnStatus] [-Wow64] [[-NewLine] <String>] [[-Context] <String>] [<CommonParameters>]
Description
Use this command with ASCII and ANSI files such as AUTOEXEC.BAT and CONFIG.SYS. Since these files do not support the Windows INI file syntax (file, section, key, value), you must precisely define the usage of commands.
All text boxes in the command dialog box contain wildcards (* and ?); they are used without the restrictions that apply to DOS commands. For example, if you create commands using *DOS*, the character sequence DOS will be found independent of leading or trailing characters (InString search). Remark lines (REM...) will be ignored because remarks would be misinterpreted as an actual command.
Parameters
-Arguments <String> |
||||||
Arguments: action (insert, delete, replace), instance (all, first, last), position (after and/or before specific lines). |
||||||
|
-ConfirmChanges <SwitchParameter> |
||||||
Ask for confirmation of each modification. |
||||||
|
-Context <String> |
||||||
User: Execution under user account; logging in HKEY_CURRENT_USER, i.e. for the user. |
||||||
|
-ContinueOnError <SwitchParameter> |
||||||
Continues script execution in spite of errors in the respective command |
||||||
|
-FileName <String> |
||||||
Name of the file to be modified. |
||||||
|
-NewLine <String> |
||||||
New line. |
||||||
|
-OldLine <String> |
||||||
Old line. |
||||||
|
-ReturnStatus <SwitchParameter> |
||||||
#TODO# |
||||||
|
-Wow64 <SwitchParameter> |
||||||
By default, the PackageDeployment module assumes to run in a 64-bit PowerShell process on 64-bit systems, and therefore defaults to the 64-bit application location (if different from the 32-bit application location) for file and registry accesses. If you want to access the 32-bit counterparts (in the file system %WinDir%\SysWOW64 instead of %WinDir%\System32, in the registry HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node instead of HKEY_LOCAL_MACHINE\SOFTWARE), use the -Wow64 switch. |
||||||
|
<CommonParameters> |
For more information about common parameters, type "Get-Help about_CommonParameters". |